INSTALLATION TIPS
-Choose a mounting location suitable to support the full weight of the system when operating
-Use minimum 1/2″ inlet water line (3/4″ preferred)
-Connect the system to the boiler feed water line only! Do not connect to the condenser water line!
-Install vertically with cartridges hanging down
-Allow 2-1/2″ clearance below the cartridge for easy cartridge replacement
-Flush cartridges by running water through filter for five minutes at full flow
OPERATION TIPS
-Change 7CB5 cartridge on a regular 6 month preventative maintenance program, when capacity is reached or when pressure falls below 10 psi
-Change SS-10 cartridge before Hydroblend compound is completely used up
-Service flow rate must not exceed 2.5 gpm for single cartridge systems or 5.0 for dual cartridge systems
-Always flush the filter cartridge at time of installation and cartridge change
-Use for periodic deliming as needed by installing the dip tube assembly in place of the SS-10 and dissolving Scale Kleen in SR-X housing. Full deliming instructions are provided with the
system
APPLICATION or SIZING
-For commercial steam applications
-For use with foodservice steamer and combi-oven applications
-The Kleensteam II Single System is shipped with one 7CB5 cartridge (for first filter head) and one filter head plug installed in the second filter head.
-Capacity is expandable by adding a second 7CB5 cartridge.