INSTALLATION TIPS
-This system must be installed and maintained according to the manufacturer?s instructions, including installation and replacement of filter cartridges
-Install vertically with cartridge hanging down
-Allow 2-1/2″ clearance below the cartridges for easy cartridge replacement
-Flush system by running water through cartridges per Installation and Use manual
OPERATION TIPS
-Change cartridges on a regular 6 month preventative maintenance program
-Change cartridges when capacity is reached or when pressure falls below 10 psi
-Service flow rate must not exceed 0.5 gpm
-Always flush the filter cartridge at time of installation and cartridge change
APPLICATION or SIZING
-For coffee service applications
-For low flow, medium volume brewers
-Rated Capacity: 3,000 gallons (11,350) or 6,000 pots