INSTALLATION TIPS
-Install vertically with cartridge hanging down
-Allow 2-1/2″ clearance below the cartridge for easy cartridge replacement
-Flush cartridge by running water through filter for three minutes at full flow
-Follow with submicron precoat filtration
OPERATION TIPS
-Change cartridges on a regular 6 month preventative maintenance program
-Change cartridges when capacity is reached or when pressure falls below 10 psi
-Always flush the filter cartridge at time of installation and cartridge change
APPLICATION or SIZING
-Problem solving and special application cartridge for extraordinary water conditions
-Capacity: 1,000 ppm gallons
-To determine cartridge life, divide total capacity of cartridge (1,000 ppm gallons) by the iron or hydrogen sulfide content of the water i.e. one cartridge will treat up to 200 gallons of water having an iron content of 5 ppm (1000 divided by 5 = 200)